SETUP RFID DOOR LOCK ACCESS CONTROL
Today our supervisor who was Mr
Mazran Bin Esro choose three persons to do this project. So, Saiful Amirin,
Faris and Hanif have been chosen to complete this project so before we get
started first we need to see Engineer Siva Kumar Subramaniam to take all the
equipments which were RFID Access Control, RFID Cards and EM Block from him. We
used model G2000-C RFID Access Control including the user’s manual to guide us
through setting process for this project. Based on the user’s manual given we
must find it on how to setup RFID Access Control, explore and learned the
process by ourselves. There were three ways to configure how the user making contact
with the RFID Access Control System which were keyfob entry, password entry,
and keyfob plus password entry but for our basic learning process Engineer Siva
Kumar Subramaniam just told us to configure the setup for keyfob entry and
password entry only.
SPECIFICATION
Working Voltage ....................... 12V DC
Unlock current .......................... up to
1A
Static current ............................. up to
60mA
Reading distance ....................... 0 – 10cm
RF Type ..................................... EM 125kHz
Working temperature ............... -10°C to +70°C
Humidity range ......................... 10% to 90% non-condensing
Dimensions................................ 117 x 117 x
21mm
CONFIGURATION JUMPERS
J1
This is used to select whether the lock is supplied power to keep it closed (NC), or is only supplied power to open the
lock (NO) Select (NO) for all 4tronix locks and releases
J2
This is used to select a high voltage (12V) or
low voltage (2V) for lock operation. This is supplied set to 12V and should be left like this for all 4tronix locks
S16
This is only used to reset the master password. See following instructions. Leave connected between Pin1 and Pin2.
INSTALLING THE SYSTEM
1.
Connect 12V DC power to pins 1 &
2, observing correct polarity
2.
Connect the
lock between pins 3 and 4
3.
Connect the
normally open lock output from a Door Entry System or a door switch (or both) to
pins
5 and 6
4.
If a door bell unit is required, connect to pins 7
and 8
CONFIGURING THE SYSTEM
A. Entering & Exiting System Configuration mode
B. Changing the master password
C. Add new user (keyfob entry)
D. Add new user (password entry)
E. Add new user (keyfob plus password entry) F. Remove one user
G. Remove all users
H. Set door open time
I. Reset Master Password
A: SYSTEM CONFIGURATION MODE
1. Normal operation mode
2. Press the ‘#’ key
3. Then press the 5-key master password (default is 12345)
4. Now in system configuration mode
5. In this mode you can perform all the configurations you need, without exiting the
mode
6. To exit configuration mode, either wait 15 seconds without pressing a button, or press ‘#’ key again
B: CHANGING THE MASTER PASSWORD
1. Enter system configuration mode (see A above)
2. Press 1
3. Enter new 5-key password (eg. 32561)
4. New master password
is accepted
|
C: ADD NEW USER (KEYFOB ENTRY)
1. Enter system configuration mode (see A above)
2. Press 2
3. Enter the 4 digit unique User ID
4. Place user’s keyfob near the keypad Buzzer sounds once
5. New keyfob user has been added
6. If the buzzer sounds three
times and lights return
then the user was already logged into the system. Try deleting the
user, then re-adding
7. If the buzzer sounds four times, then the
memory is
full
and all
250 possible users are stored. You must delete some users first before adding new ones.
D: ADD NEW USER (PASSWORD ENTRY)
1. Enter system configuration mode (see A above)
2. Press 2
3. Enter the 4-digit unique User ID
4. Enter the 6-digit
user-specific password Buzzer sounds once
5. New password user has been added
6. If
the buzzer sounds three
times and lights return to
then the user was already logged into
the system. Try deleting the user, then re-adding
7. If the buzzer sounds four times, then the
memory is
full
and all
250 possible users are stored. You must delete some users first before adding new ones.
E: ADD NEW USER (KEYFOB PLUS PASSWORD ENTRY)
1. Enter system configuration mode (see A above)
2. Press 0
3. Enter the 4-digit unique User ID
4. Place user’s keyfob near the keypad Buzzer sounds once
5. Enter the 6-digit
user-specific password Buzzer sounds once
6. New password user has been added
7. If
the buzzer sounds three
times and lights return to
then the user was already logged into
the system. Try deleting the user, then re-adding
8. If the buzzer sounds four times, then the
memory is
full
and all
250 possible users are stored. You must delete some users first before adding new ones.
F: REMOVE ONE USER
1. Enter system configuration mode (see A above)
2. Press 3
3. Enter the 4-digit User ID to delete
Buzzer sounds once
4. User is removed
G: REMOVE ALL USERS
1. Enter system configuration mode (see A above)
2. Press 4
3. All users are removed
H: SET DOOR OPEN TIME
1. Enter system configuration mode (see A above)
2. Press 5
3. Press 2 keys for door open time in seconds. So, for the
lock to
remain open for 5 seconds, enter then
4. Door open time is changed
I: RESET MASTER PASSWORD
1. Remove power from the
KeyPad
2. Move S16 jumper to pins 2
& 3
3. Replace power to KeyPad Beeps constantly
4. Remove power from KeyPad
5. Move S16 jumper back to pins 1
& 2
6. Replace power to KeyPad
7. Master Password is reset to 12345
Thank you very much for this information. The master password was changed by accident and I had no way to change it back as I had lost the instructions. But your site and info helped me to save the cost of a new keypad. Thank you
ReplyDelete